Dynisco and Viatran's wide variety of robust pressure sensors have been designed specifically for harsh and rugged environments of the Injection Molding process. Select from one of the many rugged and reliable products offered on the market today. No matter what your need for pressure measurement is, whether for nozzle measurement or mold measurement, a solution exists. |
Products
| Hydraulic Pressure Sensors | Nozzle Pressure Transducers | Nozzle Pressure Transmitters | Cavity Pressure Sensors |
| Hydraulic Pressure Sensors | |||||||
| Products | Pressure Ranges |
Output | Accuracy* | Data Sheet | Instruction Manual | ||
| PT130 | 0 - 500 psi to 0 - 10,000 psi |
3 mV/V | ± 0.5% FSO | 61 KB |
76 KB |
||
| PT140 | 0 - 500 psi to 0 - 10,000 psi |
4 - 20 mA | ± 0.5% FSO | 61 KB |
76 KB |
||
| PT150 | 0 - 500 psi to 0 - 10,000 psi |
0 - 5 Vdc | ± 0.5% FSO | 61 KB |
76 KB |
||
| PT160 | 0 - 500 psi to 0 - 10,000 psi |
0 - 10 Vdc | ± 0.5% FSO | 61 KB |
76 KB |
||
| PT160SW | 0 - 500 psi to 0 - 10,000 psi |
on/off | n/a | 59 KB |
No Manual | ||
| 243 | 0 - 100 psi to 0 - 15,000 psi |
0 - 5 Vdc | ± 0.5% FSO | 180 KB |
91 KB |
||
| 343 | 0 - 100 psi to 0 - 15,000 psi |
4 - 20 mA | ± 0.5% FSO | 180 KB |
91 KB |
||
| 247 | 0 - 5 psi to 0 - 20,000 psi |
0 - 5 (0 - 10) Vdc | ± 0.5% FSO | 136 KB |
153 KB |
||
| 347 | 0 - 5 psi to 0 - 20,000 psi |
4 - 20 mA | ± 0.5% FSO | 136 KB |
153 KB |
||
| 148 | 0 - 15 psi to 0 - 15,000 psi |
2.5 - 10 mV/V | ± 0.25% FSO | 83 KB |
137 KB |
||
| 248 | 0 - 15 psi to 0 - 15,000 psi |
0 - 5 Vdc | ± 0.25% FSO | 83 KB |
137 KB |
||
| 348 | 0 - 15 psi to 0 - 15,000 psi |
4 - 20 mA | ± 0.25% FSO | 83 KB |
137 KB |
||
| Nozzle Pressure Transducers | |||||||
| Products | Pressure Ranges |
Output | Accuracy* | Data Sheet | Instruction Manual | ||
| PT467E | 0 - 500 psi to 0 - 30,000 psi |
3.33 mV/V | ± 0.5% FSO | 69 KB |
121 KB |
||
| PT467E-M10 | 0 - 5,000 psi to 0 - 10,000 psi |
3.33 mV/V | ± 1.0% FSO | 160 KB |
121 KB |
||
| PT435A | 0 - 500 psi to 0 - 30,000 psi |
3.33 mV/V | ± 0.25% FSO | 69 KB |
121 KB |
||
| PT465XL | 0 - 3,000 psi to 0 - 15,000 psi |
3.33 mV/V | ± 0.5% FSO | 66 KB |
121 KB |
||
| PT467XL | 0 - 3,000 psi to 0 - 30,000 psi |
3.33 mV/V | ± 1.0% FSO | 67 KB |
121 KB |
||
| Nozzle Pressure Transmitters | |||||||
| Products | Pressure Ranges |
Output | Accuracy* | Data Sheet | Instruction Manual | ||
| PT4674 | 0 - 500 psi to 0 - 30,000 psi |
4 - 20 mA | ± 0.5% FSO | 103 KB |
1.34 MB |
||
| PT4674 "A" | 0 - 500 psi to 0 - 30,000 psi |
4 - 20 mA | ± 0.5% FSO | 101 KB |
1.35 MB |
||
| PT4675 | 0 - 500 psi to 0 - 30,000 psi |
0 - 5 Vdc | ± 0.5% FSO | 69 KB |
537 KB |
||
| PT4676 | 0 - 500 psi to 0 - 30,000 psi |
0 - 10 Vdc | ± 0.5% FSO | 69 KB |
537 KB |
||
| MDT467X | 0 - 100 bar to 0 - 2,000 bar |
4 - 20 mA | ± 0.5% f.s.v. | 160 KB |
567 KB |
||
| MDT435X | 0 - 35 bar to 0 -2000 bar |
4 - 20 mA | ± 0.5% f.s.v. | 160 KB |
567 KB |
||
| PT4654XL | 0 - 3,000 psi to 0 - 20,000 psi |
4 - 20 mA | ± 1.0% FSO | 106 KB |
1.34 MB |
||
| PT4654XL "A" | 0 - 3,000 psi to 0 - 20,000 psi |
4 - 20 mA | ± 1.0% FSO | 105 KB |
1.35 MB |
||
| PT4655XL | 0 - 3,000 psi to 0 - 20,000 psi |
0 - 5 Vdc | ± 1.0% FSO | 63 KB |
537 MB |
||
| PT4656XL | 0 - 3,000 psi to 0 - 20,000 psi |
0 - 10 Vdc | ± 1.0% FSO | 63 KB |
537 MB |
||
| Cavity Pressure Sensors | |||||||
| Products | Pressure Ranges |
Output | Accuracy* | Data Sheet | Instruction Manual | ||
| FT444DH | 50 lbs. to 2,200 lbs. |
2.0 - 2.2 mV/V | ± 0.5% FSO | 59 KB |
109 KB |
||
| FT445H | 50 lbs. to 2,200 lbs. |
2.0 - 3.0 mV/V | ± 0.5% FSO | 64 KB |
109 KB |
||
| FT446H | 50 lbs. to 2,200 lbs. |
2.0 - 2.2 mV/V | ± 0.5% FSO | 64 KB |
109 KB |
||
| FT446HM | 50 lbs. to 2,200 lbs. |
2.0 - 2.2 mV/V | ± 0.5% FSO | 64 KB |
109 KB |
||
| * Accuracy is defined as the maximum combined error of Linearity (BSL), Repeatability, and Hysterisis as defined by ISA-37.3. |
|||||||